NO.1 A FAS6280 running ONTAP 8.0.2 HAS A 32-bit root aggregate. After upgrading to Data ONTAP
8.1, what is the status of the root aggregate?
A. The root aggregate remains 32-bit
B. The root aggregate converts from 32 to 64-bit in place
C. The root aggregate auto-migrates to a new 64-bit aggregate
D. The upgrade fails with a message to create a new 64-bit aggregate before upgrade
Answer: A
Network Appliance exam fragen NS0-157 PDF Testsoftware NS0-157 NS0-157 Unterlage
NO.2 An administrator for a virtual server named abc17 mounts a new volume named vola at
junction named / accounting/teama and creates two directories at the root of the new volume
named 2011 and 2011/june. Healso copies a file called report.doc into the directory named june. An
NFS client mounts to the root of the namespace. What is the fully qualified path to the report.doc?
A. /abc17/accounting/teama/2011/june/report.doc
B. /accounting/teama/2011/june/report.doc
C. /accounting/vola/teama/2011/june/report.doc
D. /vol/vola/2011/june/report.doc
E. Z:\vola\2011\june\report.doc
Answer: B
Network Appliance fragen beantworten NS0-157 NS0-157 echte fragen
NO.3 What are two FPolicy methods for applications? (Choose two.)
A. asynchronous
B. semi-synchronous
C. direct
D. synchronous
Answer: A,D
Network Appliance fragen und antworten NS0-157 exam fragen NS0-157 online tests NS0-157 echte fragen
Reference: https://library.netapp.com/ecmdocs/ECMP1196891/html/GUID-CFED10C9311A-444C-
8684-D7BBAF0BFADC.html
NO.4 Which of the following steps must be completed before a CIFS share can be active?
A. Configure name mapping
B. License both NFS and CIFS
C. Create a data LIF for the CIFS server on every node
D. Reboot the node containing the CIFS Vserver root volume
Answer: A
Network Appliance Schulungsunterlagen NS0-157 prüfung NS0-157 Examsfragen NS0-157 Prüfungsfrage
NO.5 A customer wants to improve write performance on their FAS2552 HA system. The system is
built with SAS drives, and they are not interested in purchasing additional disk shelves. The workload
consists of mostly small, random overwrites and random reads.
What should the customer do to improve performance?
A. Enable free space reallocation on the aggregate.
B. Enable FlashCache on both nodes.
C. Increase the amount of NVRAM in the system.
D. Assign a Flash Pool RAID group to the aggregates.
Answer: D
Network Appliance originale fragen NS0-157 Fragenpool NS0-157 Fragenkatalog NS0-157 quizfragen und antworten NS0-157 prüfung
Explanation:
A Flash Pool is built from a Data ONTAP aggregate in a two-step process, described in section 3,1, "7-
Mode CLI." Essentially it is the addition of SSDs into an aggregate to provide a high-bandwidth, low-
latency location that is capable of caching random reads and random overwrites.
http://community.netapp.com/fukiw75442/attachments/fukiw75442/data-
ontapdiscussions/17208/1/43347_TR4070_NetApp_Flash_Pool_Design_and_Implementation_Guide.
pdf
NO.6 Which aggregate type is supported for Flash Pool?
A. Traditional
B. 32-bit
C. 64 bit
D. 128-bit
Answer: C
Network Appliance echte Fragen NS0-157 online tests NS0-157 Fragenkatalog
Explanation:
Flash Pool Design and Implementation Guide
NO.7 Node cl-02 needs to fail over for scheduled maintenance. The node has NAS LIFs on it. The
failover needs to be non-disruptive to the NAS clients.
Which command accomplishes this task?
A. system node halt -ofnode cl - 02 -inhibit true
B. system node reboot -ofnode cl - 02 -inhibit-takeover true
C. storage failover takeover -ofnode cl - 02 -bypass -optimization true
D. storage failover takeover -ofnode cl - 02
Answer: C
Network Appliance quizfragen und antworten NS0-157 zertifizierungsantworten NS0-157 prüfungsfragen NS0-157 Zertifizierungsantworten
Explanation:
The aggregate relocation can be avoided during this takeover instance by using the
bypassoptimization parameter with the storage failover takeover command. To bypass aggregate
relocation during all future planned takeovers, set the bypasstakeoveroptimization parameter of the
storage failover modify command to true.
Reference:http://www-01.ibm.com/support/docview.wss?uid=ssg1S7004761&aid=1
NO.8 What are two defaults for a new Data ONTAP 8.1 or later system root aggregate? (Choose two.)
A. 32-bit
B. 64-bit
C. 0% aggr reserve
D. 5% aggr reserve
Answer: B,C
Network Appliance zertifizierungsfragen NS0-157 Schulungsunterlagen NS0-157 prüfungsfrage NS0-157 Testfagen NS0-157 Unterlage
Wenn man an sich glaubt, kann man wirklich was erreichen. Der Grund, warum ZertPruefung jedem IT-Fachmann helfen kann, liegt in seiner Fähigkeit. Die Prüfungsmaterialien zur Network Appliance NS0-157 Zertifizierung von ZertPruefung können Ihnen zum Erfolg verhelfen. Jede Beschränkung fängt im Herzen an. Wenn Sie die Network Appliance NS0-157 Prüfung bestehen wollen, werden Sie ZertPruefung wählen. Eigentlich ist die Distanz zwischen Erfolg und Niederlage nicht weit. ZertPruefung führt Sie zum Erfolg.
Die Network Appliance NS0-157 Zertifizierungsprüfung ist der erste Schritt zum Berufserfolg fur IT-Fachleute. Durch die Network Appliance NS0-157 Zertifizierungsprüfung haben Sie schon den ersten Fuß auf die Spitze Ihrer Karriere gesetzt. ZertPruefung wird Ihnen helfen, die Network Appliance NS0-157 Zertifizierungsprüfung zu bestehen.
Machen Sie sich noch Sorgen um die Network Appliance NS0-157 Zertifizierungsprüfung? Warten Sie noch mühlos auf die neuesten Materialien zur Network Appliance NS0-157 Zertifizierungsprüfung? ZertPruefung hat neulich die neuesten Materialien zur Network Appliance NS0-157 Zertifizierungsprüfung bearbeitet. Wollen Sie die Network Appliance NS0-157 Zertifizierungsprüfung bestehen? Bitte schicken Sie doch schnell die Fragen und Antworten zur Network Appliance NS0-157 Zertifizierungsprüfung in den Warenkorb! Sie können kostenlos die Demo auf der Website ZertPruefung.de herunterladen, um unsere Zuverlässigkeit zu bestätigen. Wir versprechen, dass wir Ihnen die gesammte Summe zurückerstatten werden, falls Sie mit unseren Prüfungsmaterialien in der Network Appliance NS0-157 (NetApp Certified Data Administrator, Clustered Data ONTAP) Zertifizierungsprüfung durchfallen.
Prüfungsname: NetApp Certified Data Administrator, Clustered Data ONTAP
Aktulisiert: 2015-09-22, NS0-157 Prüfungsunterlagen
Nummer: 303 Q&As
NS0-157 antworten : NS0-157 Prüfungsunterlagen
Es ist eine weise Wahl, sich an der Network Appliance NS0-157 Zertifizierungsprüfung zu beteiligen. Mit dem Network Appliance NS0-157 Zertifikat werden Ihr Gehalt, Ihre Stelle und auch Ihre Lebensverhältnisse verbessert werden. Es ist doch nicht so einfach, die Network Appliance NS0-157 Zertifizierungsprüfung zu bestehen. Sie nehmen viel Zeit und Energie in Anspruch, um Ihre Fachkenntnisse zu konsolidieren. ZertPruefung ist eine spezielle Schulungswebsite, die Schulungsprogramme zur Network Appliance NS0-157 (NetApp Certified Data Administrator, Clustered Data ONTAP) Zertifizierungsprüfung bearbeiten. Sie können zuerst die Demo zur Network Appliance NS0-157 Zertifizierungsprüfung im Internet als Probe kostenlos herunterladen, so dass Sie die Glaubwürdigkeit unserer Produkte testen können. Normalerweise werden Sie nach dem Probieren unserer Produkte Vertrauen in unsere Produkte haben.
NS0-157 prüfungsfragen Demo kostenlos downloden: http://www.zertpruefung.ch/NS0-157_exam.html
Keine Kommentare:
Kommentar veröffentlichen